Losing all data after filter step using SGA
1
0
Entering edit mode
9.6 years ago
jolespin ▴ 150

Raw fastq > preprocess > index > correct > index = processed_reads.ec.fa (6.5 GB)

I've taken the processed_reads.ec.fa and ran the following command:

sga filter -k 31 processed_reads.ec.fa

stderr:

sga: QCProcess.cpp:233: DuplicateCheckResult QCProcess::performDuplicateCheck(const SequenceWorkItem&): Assertion `fwdIntervals.interval[0].isValid() || rcIntervals.interval[0].isValid()' failed.

stdout:

...
[sga] Processed 8000000 sequences (912.782961s elapsed)
[sga] Processed 8050000 sequences (918.024303s elapsed)
[sga] Processed 8100000 sequences (925.718005s elapsed)
[sga] Processed 8150000 sequences (932.858792s elapsed)
Abort (core dumped)

The output files were:

processed_reads.ec.filter.pass.fa #(1.4 MB)
processed_reads.ec.discard.fa #(2.0 GB)

Does anyone know what's happening? What are these errors? I've tried different thread sizes and different kmer sizes and have not seen any significant improvements.

kmer SGA filter assemly • 1.9k views
ADD COMMENT
1
Entering edit mode
9.6 years ago
jolespin ▴ 150

Needed the BWT file from the reindexing step

ADD COMMENT