What Aligner To Use For Paired-End 454 Reads?
1
1
Entering edit mode
12.9 years ago
Bioscientist ★ 1.7k

I read BWA manual. Seems for 454 longer reads, it's recommended to use BWA -BWASW, which only supports single-end reads.

Then what about 454 paired-end reads?Use bowtie? Also, 454 contain reads with variable length. Then how to deal with those very short reads? (I see some reads are only 10bp..) thx

@SRR000945.10444  E78I8DJ01CQCVG  length=108
TGACTTTGTAATTTCCATATTTAAATTCCTTCATCTGATTTTCAGCTTCTCAGGGAAACCACCTAATATCCCTACCAGACAGTCATCTTTCATCTACTGAATAATTCC
+
AAABAAA====AABAAABBA@@AAAAAAABBBBBBBBB@@@@BBBBBBBBBBBAAAAAAABABBBBAAAAAAA@??AAAAAA???@=<<<@??????@@@@?==9995
@SRR000945.10446  E78I8DJ01A06WQ  length=10
AACTCCCAGA
+
555=555995
@SRR000945.10447  E78I8DJ01A1GWE  length=48
GCTCAAATAGTTATCTTCCCTGAGATGCCTCCCACTAACTCACAATCG
+
AAAA@@@A???AAAA??===?AAAAAA@@@?????@@@???????===
• 3.7k views
ADD COMMENT
0
Entering edit mode

the paired end vs single end reads are generated with the samse and sampe commands and I don't think the way you align aln or bwasw matters.

ADD REPLY
0
Entering edit mode

An obvious choice would be Newbler. If you can't use that, you could try GMAP. I don't have enough experience with the whole range of aligners to make a specific recommendation, though.

ADD REPLY
0
Entering edit mode

i am frankly surprised the 454 would report a 10bp read

ADD REPLY
0
Entering edit mode

see the edit plz......yeah, it does have 10bp read...or maybe this is not 454?

ADD REPLY
0
Entering edit mode

hi istvan; so for 454 paired-end reads, I simply regard them as illumina/solexa? I mean; first "bwa aln", then "bwa sampe" ?

ADD REPLY
3
Entering edit mode
12.9 years ago
lh3 33k

BWASW-0.6 supports paired-end reads (as you know, BWA does not work with 454). Smalt is a good one. Bowtie2 should also work well, though I have not tried this myself. A caveat with Bowtie2 I found recently is that for a gap in a tandem repeat where the gap placement is uncertain, bowtie2 places the gap in a largely random position in the repeat (see this). This may pose challenges to some SNP/indel caller such as samtools which assume the mapper tries best to put the gap at the leftmost position. It is also fair to say this is a weakness of samtools. I used to try GMAP a few years ago. At that time, its performance was not as good as mappers more tuned for reads mapping, but this may be changed recently.

ADD COMMENT
0
Entering edit mode

sorry i'm still confused. Can I regard them as illumina/solexa? I mean; first "bwa aln", then "bwa sampe" ?

ADD REPLY
0
Entering edit mode

No, 454 reads have high homopolymer indel error rate. aln+sampe would not work well.

ADD REPLY

Login before adding your answer.

Traffic: 1465 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6