Can I get a hit by WGS but not by PCR?
1
0
Entering edit mode
4.5 years ago

Hello,

I performed a WGS with Illumina on three histological sections. I looked for viral genomes and I got one hit for Epstein-Barr virus. Then I performed PCR to confirm the data and I got an unclear result for the sample positive by WGS and two positives for the other two samples.

How shall I consider this analysis? That the WGS was garbage? Is there a way that PCR and WGS could give different values? for instance, the sections were different...

Thank you

sequencing next-gen confirmation PCR • 1.4k views
ADD COMMENT
0
Entering edit mode
4.5 years ago
Joe 21k

Most likely your PCR wasn't optimised and you have non-specific results or something.

We don't know how you "looked for viral genomes" so its hard to suggest issues or otherwise.

To me, the obvious first thing to do would be repeat the PCR.

ADD COMMENT
0
Entering edit mode

I am not concerned about the one negative PCR but the two positive ones: they disprove the WGS analysis... I used a concatenated genome with all the viral sequences in GeneBank, added it to the human genome and aligned with BWA. But simple there are no reads.

ADD REPLY
0
Entering edit mode

Wouldn't simply putting together a lot of virus sequences create a lot of sequence-identical (or at least highly similar) contigs resulting in multimappers which in turn lead to no counts for all these sequence-identical regions? I cannot comment further since, as Joe says, your question lacks any details what you exactly did and what the samples were.

ADD REPLY
0
Entering edit mode

You probably need to tell us more about what 'positive' looks like in your WGS? How many reads? What coverage of the genome?

My bet is on multi mapping or something if the WGS is 'wrong', but more likely false positives in your PCR through contamination, mixed up samples, or something.

ADD REPLY
0
Entering edit mode

On IGV the positive (bottom alignment) looks like this: enter image description here This sample had 10 reads about 100 bp each. By extracting the EBV chromosome, I got these for the positive WGS / negative PCR sample:

samtools view -b -h <file.bam> "chrEBV" | samtools flagstat 
95 + 0 in total (QC-passed reads + QC-failed reads)
0 + 0 secondary
1 + 0 supplementary
0 + 0 duplicates
95 + 0 mapped (100.00% : N/A)
94 + 0 paired in sequencing
47 + 0 read1
47 + 0 read2
94 + 0 properly paired (100.00% : N/A)
94 + 0 with itself and mate mapped
0 + 0 singletons (0.00% : N/A)
0 + 0 with mate mapped to a different chr
0 + 0 with mate mapped to a different chr (mapQ>=5)

compared to a negative WGS / positive PCR:

15 + 0 in total (QC-passed reads + QC-failed reads)
0 + 0 secondary
0 + 0 supplementary
0 + 0 duplicates
15 + 0 mapped (100.00% : N/A)
15 + 0 paired in sequencing
8 + 0 read1
7 + 0 read2
12 + 0 properly paired (80.00% : N/A)
15 + 0 with itself and mate mapped
0 + 0 singletons (0.00% : N/A)
3 + 0 with mate mapped to a different chr
0 + 0 with mate mapped to a different chr (mapQ>=5)
ADD REPLY
1
Entering edit mode

It seems very unlikely that 10 reads reflects any sort of biological reality. These are probably multimappers/low quality reads or just happen to have some bits of sequence that are shared between viral motifs/human motifs.

I would suggest looking at the mapping file for those reads and considering whether they're garbage or not.

ADD REPLY

Login before adding your answer.

Traffic: 1710 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6