What QC measures to look for when performing deconvolution?
0
1
Entering edit mode
3.4 years ago
Aspire ▴ 370

In a dataset with ~100 (human) samples in the control, ~80 samples in the treatment, DESeq2 found only one significant gene.

I have performed deconvolution (with tpm values of the same data) with CibersortX (but with a signature matrix from another source).

I used group-mode in CibersortX and then used the script suggested by CibersortX team in their article to find the significantly DE genes

for (i in 1:ncol(geps1)){
vBetaZ <- sapply(1:nrow(geps1), function(j) (geps1[j,i]-geps2
[j,i])/sqrt(stderr1[j,i]^2+stderr2[j,i]^2))
ZPs <- 2*pnorm(-abs(vBetaZ))
Zqvals <- p.adjust(ZPs, method=“BH”)
}

Where geps1, geps2 are the group expression profile for control and treatment.

After filtering results for average expression in geps1&geps2 > 0.3, taking abs(log2foldchange) > 1, and taking p-adj of 0.05 I get a few hundreds of significant genes per cell-type (300-400 in TCD8 & TCD4, 100-200 in Monocytes, NK, Basophils, Neutrophils).

What QC measures should I use?

How can I verify that the signal after deconvolution is real?

QC CibersortX deconvolution • 1.4k views
ADD COMMENT
1
Entering edit mode

I have performed a permutation test. It is not specific to deconvolution in any way, but a good test to perform generally.

After permuting the labels of the condition (leaving the same number of samples for control/treatment), there still are hundreds of significant genes for the major cell types. So the strength of the original signal (in the OP) does not seem to reflect anything real.

If anyone can offer an explanation why would CibersortX deconvolution yield such a number (hundreds) of false positives per cell type (they probably are false positives as the assignment to condition/treatment group was random) - I'd be glad to hear.

( I guess that the Z-test employed to test for difference between the groups' expression profiles is too permissive ).

ADD REPLY
1
Entering edit mode

So the strength of the original signal (in the OP) does not seem to reflect anything real.

I would have bet money on that even before you did the permutation. If DESeq2, one of the most well-tested and established gene-level DE tools, does not yield any DE results then it is most unlikely that a second method yield hundreds of DEs which are meaningful. Sure, different methods may produce different results, maybe 10 DEs in method A and 50 in method B but 1 vs hundreds is highly suspicious. I do not know CibersortX, but my recommendation would be to stick with established tools and rather try to find the reason why there are no DEs (given that your expectation based on phenotype/biology is that there are DEs). Maybe batch effects or some other kinds of confounders? Or there are simply none, even though this is very unlikely at this sample size. if you show some code and PCA plots maybe one can help debugging.

ADD REPLY
0
Entering edit mode

I would trust the result after deconvolution since the initial tissues are mixture samples and we don't the weight for each component.

ADD REPLY

Login before adding your answer.

Traffic: 1598 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6