Please help me with the MultiQC results
1
1
Entering edit mode
2.6 years ago
arr234 ▴ 40

Hi. I have performed MultiQC for 100 paired end reads after filtering using Cutadapt. But the result shows only for the 2nd end read for all the 100. So does the results include both forward and reverse reads?enter image description here

Even after filtering using Cutadapt, the MultiQC results show many short reads as shown in the image below. So what should I do? Should I redo Cutadapt with different minimum length and quality cutoff set or will it affect the results? enter image description here

MULTIQC NGS FASTQC Cutadapt • 1.5k views
ADD COMMENT
0
Entering edit mode

your question is ill-formed, multiqc summarizes other reports, it does not select files to run analyses on, it does not generate original reports, it simply summarizes existing reports

have you performed the processes on each file? can you see the individual reports for each file?

ADD REPLY
1
Entering edit mode
2.6 years ago
Phil Ewels ★ 1.4k

But the result shows only for the 2nd end read for all the 100. So does the results include both forward and reverse reads?

I have a feeling off the top of my head, that if you run Cutadapt in paired-end mode then MultiQC can end up naming your samples after just one of the input FastQs like this. So I suspect that it's fine, but please manually check at least one of the cutadapt log files to sanity check and make sure that it looks ok.

Even after filtering using Cutadapt, the MultiQC results show many short reads as shown in the image below.

Does the image show that? To me I see most of the samples with mostly light-blue bars, which is the category "passed filters". These are the reads that were not filtered out, that successfully passed on into the resulting FastQ files for downstream analysis.

You have one sample with a significant fraction of reads categorised as "Pairs that were too short", which are reads that were lost. This sample likely suffered from significant adapter contamination.

Changing the cutoff will affect the results, but whether it's something you should do or not depends on your biological question, input sample setup and downstream analysis. I doubt that it's something that you need to or want to do.

ADD COMMENT
0
Entering edit mode

Thanks for the detailed response Mr. Ewels. I just want to clarify. So that one sample with a significant fraction of reads categorized as "Pairs that were too short" are already removed by Cutadapt and the FASTQ file generated at the end of Cutadapt analysis has only the reads that fall under the "passed filters"? Right?

ADD REPLY
0
Entering edit mode

Probably, but it depends on exactly how you ran Cutadapt. I'd recommend that you read over https://cutadapt.readthedocs.io/en/stable/guide.html#filtering and, most importantly, check the raw log files from cutadapt if you're unsure. MultiQC is only ever for summary statistics and the "ground truth" is always the source log files.

ADD REPLY

Login before adding your answer.

Traffic: 2194 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6